Overview of Bitumen Demand in Tanzania
Tanzania, a rapidly developing country in East Africa, has a thriving construction and infrastructure sector. The growth has created an increased need for quality bitumen to support road construction, urbanization, and industrial applications. As a trusted Bitumen Supplier in Tanzania, ZUMRUT INT Co. provides high-quality bitumen, including 60/70, 80/100, and 40/50, to international quality standards for various construction projects.
Types of Bitumen and Their Use in Tanzania
Bitumen 60/70
Medium-hard penetration grade bitumen is extensively used in road and asphalt paving. Bitumen 60/70, specifically, is best applicable in Tanzania, whose climatic conditions vary from humid coastlines to semi-arid mainlands. Hence, bitumen 60/70 is ideal for the paving of highways as well as city roads that demand high temperature resistance and high traffic load resistance.
Bitumen 80/100
A softer bitumen grade suitable for regions with mild climates and roads with low traffic. Bitumen 80/100 is typically used in rural roads and surface dressings in Tanzania, having the capacity to remain flexible and resistant to temperature changes.
Bitumen 40/50
A harder grade of bitumen for situations that demand greater strength and durability. Typically used in heavy-traffic highways, airport runways, and bridges in Tanzania, bitumen 40/50 performs well in high-stress areas.
Bitumen Waterproofing Solutions for Tanzania
Given the varied climate of Tanzania, ranging from the coastal humid to drier regions inland, bitumen is extensively used in waterproofing to shield buildings from water damage. Some of the most important uses are:
Roofing Systems: Bitumen coating is applied to avert water penetration, particularly in coastal regions such as Dar es Salaam.
Basement Waterproofing: Bitumen solutions are applied to avert groundwater seepage and foundation damage in urban and rural areas.
Concrete and Bridge Protection: Extending the life of bridges and concrete structures so they can withstand the test of time.
Underground Construction: Bitumen is critical in protecting tunnels and underground constructions from damage induced by moisture.
Major Bitumen Import Ports in Tanzania
Tanzania’s main ports have a crucial role to play when it comes to importing bitumen and other essential materials. Some of the main ports include:
- Port of Dar es Salaam (the largest and busiest port in Tanzania)
- Port of Tanga
- Port of Mtwara
These seaports facilitate the easy transport of bitumen and other materials required for Tanzania’s infrastructural development projects.
Major Bitumen Suppliers in Tanzania
There are several local and international suppliers to fulfill Tanzania’s demand for quality bitumen. Some of the well-known suppliers include:
National Oil Company of Tanzania (NOCT): A government-owned company providing bitumen for local infrastructure projects.
Austrobitumen: A leading distributor of bitumen products for construction and industrial markets in Tanzania.
Prime Engineering and Trading Co. Ltd.: It is well known for providing high-quality bitumen for the construction of roads and waterproofing applications across the country.
International firms like ZUMRUT INT Co. also play a significant role in supplying high-quality bitumen to meet Tanzania’s infrastructure needs.
Price of Bitumen in Tanzania
The price of bitumen in Tanzania is influenced by several key factors, including fluctuations in crude oil prices, ocean freight costs, the price of vacuum bottom (VB), and the type of packaging used. Among the different bitumen grades, the price of bitumen 60/70 serves as the benchmark, as it is the lowest and forms the base price for other grades. The price of cutback bitumen, on the other hand, depends on the cost of its primary raw materials.
Our payment Term
Our terms of payment are TT/30% in advance and balance after a copy of BL. This secures 30% of the payment in advance while the remaining balance is settled when a copy of the Bill of Lading has been availed, ensuring goods are in transit and well documented.
Order Now
To place an order for bitumen in Tanzania, customers can start by selecting the required grade and type of packaging. After confirming the specifications, an official quotation and proforma invoice will be issued. Upon agreement, the customer proceeds with the payment according to the provided terms. Once payment is received, the shipment process will begin, including coordination for delivery to the specified destination in Tanzania. Our team will assist at every step to ensure a smooth and timely supply. As a Bitumen Supplier in Tanzania, our team will assist at every step to ensure a smooth and timely supply. (Contact Us)
Why Choose Us?
We at ZUMRUT INT Co. pride ourselves on being a leading Tanzania Bitumen Supplier of high-performance and long-lasting bitumen products to international standards. As a trustworthy Tanzania Bitumen Supplier, we are dedicated to timely and consistent delivery to Tanzania’s growing infrastructure economy. We are a competitive Tanzania Bitumen Supplier who is within reach, especially for bulk orders. We test our bitumen rigorously to deliver the best quality and long-lasting performance. Besides, we offer flexible packaging solutions to suit various construction and industrial needs. With our technical know-how and complete customer assistance, we are the ideal Tanzania Bitumen Supplier for your project. Contact us today to discuss your unique.
Specification
Bitumen 60/70
Bitumen 60/70 | Test method | Unit | Specification |
---|---|---|---|
Specific gravity @ 25°C | ASTM D70 | Kg/cm3 | 1.01/1.06 |
Penetration @ 25°C | ASTM D5 | mm/10 | 60/70 |
Softening point °C | ASTM D36 | °C | 49/56 |
Ductility @25 °C | ASTM D113 | cm | 100 min |
Loss on heating(wt) % | ASTM D6 | wt % | 0.2 max |
Drop in penetration after heating % | ASTM D5-D6 | % | 20 max |
Flashpoint °C | ASTM D92 | °C | 232 min |
Solubility in Trichloroethylene | ASTM D2042 | wt % | 99 min |
Spot test | A.A.S.H.O.T102 | Negative |
Bitumen 80/100
Bitumen 80/100 | Test method | Unit | Specification |
---|---|---|---|
Specific gravity @ 25°C | ASTM D70 | Kg/cm3 | 1.01/1.06 |
Penetration @ 25°C | ASTM D5 | mm/10 | 80/100 |
Softening point °C | ASTM D36 | °C | 42/50 |
Ductility @25 °C | ASTM D113 | cm | 100 min |
Loss on heating(wt) % | ASTM D6 | wt % | 0.2 max |
Drop in penetration after heating % | ASTM D5-D6 | % | 20 max |
Flashpoint °C | ASTM D92 | °C | 250 min |
Solubility in CS2(wt) % | ASTM D4 | wt % | 99.5 min |
Spot test | A.A.S.H.O.T102 | Negative |
Bitumen 40/50
Bitumen 40/50 | Test method | Unit | Specification |
---|---|---|---|
Specific gravity @ 25°c | ASTM D70 | Kg/cm3 | 1.01/1.06 |
Penetration @ 25°c | ASTM D5 | mm/10 | 40/50 |
Softening point °c | ASTM D36 | °C | 52/60 |
Ductility @25 °c | ASTM D113 | cm | 100 min |
Loss on heating(wt) % | ASTM D6 | wt % | 0.2 max |
Drop in penetration after heating % | ASTM D5-D6 | % | 20 max |
Flash point °c | ASTM D92 | °C | 250 min |
Solubility is CS2(wt) % | ASTM D4 | wt % | 99.5 min |
Spot test | A.A.S.H.O.T102 | _____ | Negative |