Anionic Bitumen Emulsion SS-1

Description of Bitumen Emulsion Anionic SS-1

Anionic Bitumen Emulsion SS-1 is a slow-setting anionic asphalt emulsion (i.e., low reactivity) low viscosity, and a hard asphalt residue that is designed for various paving and industrial uses. Asphalt emulsions are classified according to the electric charge that surrounds the emulsion’s asphalt particles (i.e. whether it is a cationic or an anionic emulsion) and how quickly the suspended asphalt particles separate from the surrounding water (“breaking”).

For anionic and Emulsions, there are several grades of different braking characteristics. Rapid-setting emulsions are used for surface dressing, while medium or slow-setting emulsions are used for ‘mixtures’, that are mixed with aggregate either in concrete-type mixers or in situ. Therefore, stone mixtures require medium-setting emulsions and sand mixtures require a slow-breaking emulsion. With anionic emulsions, the breaking process is predominantly by evaporation of the water in the emulsion continuous phase. Because of this, anionic emulsions are susceptible to temperature and humidity in terms of their breaking properties.

Application of Emulsion Anionic SS-1

The main applications of Anionic bitumen emulsion are waterproofing, building application, highway construction, surfacing, and maintenance. Anionic emulsion is obtained by an electric field. In an anionic emulsion, the droplets migrate from the anode. Anionic bitumen emulsion SS-1 is a slow setting, anionic type of Asphalt. special emulsifiers, water, and other additive have been gone through anionic Slow Setting Asphalt Mixture is the cold/non-fibered liquid applied waterproofing Asphalt Mixture .

Packing 

Packing of this is in the new thick steel drum on the pallet to prevent any leak inside of container also bulk in bitutainer and tanker.

Specification

PROPERTYMINMAXTEST METHOD
Viscosity SSF, 25 °C (s)20100ASTM D244
Viscosity SSF, 50 °C (s)__________ASTM D244
Storage stability, 24h (%)_____1ASTM D6930
Demulcibility  , 0.02 N CaCl2 (%)_______________
Cement mixing (%)_____2_____
Sieve (%)_____0.1ASTM D6933
Residue (%)57_____ASTM-D244
Solubility in trichloroethylene %97.5_____ASTM D2042
Penetration 77°F (25°C) 100g,5s mm100200ASTM D5
ductility, 77°F (25 °C), 5cm/min (cm)40_____ASTM D113

Leave a Reply